Suitable for Submersible Pump & Open well Pump Protections against Over load & Dry Run with Starting & Running Capacitors.
Available for 0.5 H.P., 0.75 H.P., 1 H.P., 1.5 H.P. and 2 H.P.
H.P. | 0.5 H.P. | 0.75 H.P. | 1 H.P. | 1.5 H.P. | 2 H.P. |
---|---|---|---|---|---|
Running Capacitor | 25 Mfd | 30 Mfd | 36 Mfd | 36+25 Mfd | 36+36 Mfd |
Starting Capacitor | 100/120 Mfd | 100/120 Mfd | 100/120 Mfd | 120/150 Mfd | 150/200 Mfd |
P | N | R | Y | B |
---|---|---|---|---|
230VAC. SUPPLY | TO MOTOR |
Suitable for Single Phase Submersible Pumps with Starting and Running Capacitor with overload protection.
Available for- 0.5 H.P., 0.75 H.P., 1 H.P., 1.5 H.P., 2 H.P.
H.P. | 0.5 H.P. | 0.75 H.P. | 1 H.P. | 1.5 H.P. | 2 H.P. |
---|---|---|---|---|---|
Running Capacitor | 25 Mfd | 30 Mfd | 36 Mfd | 36+25 Mfd | 36+36 Mfd |
Starting Capacitor | 100/120 Mfd | 100/120 Mfd | 100/120 Mfd | 120/150 Mfd | 150/200 Mfd |
P | N | R | Y | B |
---|---|---|---|---|
230VAC. SUPPLY | TO MOTOR |
Suitable for Single Phase Submersible Pump controlling both Suction and Delivery Tank, operating on Sensor or Float Switch with Auto cut off to Starting Capacitor.
Protection against Overload and Dry Run.
Available for- 0.5 H.P., 0.75 H.P., 1 H.P., 1.5 H.P., 2 H.P.
H.P. | 0.5 H.P. | 0.75 H.P. | 1 H.P. | 1.5 H.P. | 2 H.P. |
---|---|---|---|---|---|
Running Capacitor | 25 Mfd | 30 Mfd | 36 Mfd | 36+25 Mfd | 36+36 Mfd |
Starting Capacitor | 100/120 Mfd | 100/120 Mfd | 100/120 Mfd | 120/150 Mfd | 150/200 Mfd |
P | N | R | Y | B |
---|---|---|---|---|
230VAC. SUPPLY | TO MOTOR |
Suitable for Three Phase Submersible Pump, Openwell Submersible Pump and Monoblock Pump.
Protection against Overload and Dry Run, Single Phasing, Reverse Phasing, Unbalance Voltage etc.
R | Y | B | R | Y | B |
---|---|---|---|---|---|
440 VAC. | TO MOTOR |
Suitable for Three Phase Submersible Pump, Open Well & Monoblock Pump Protection against Overload, Dry Run, Single Phasing, Reverse Phasing & Unbalance Voltage
R | Y | B | R | Y | B |
---|---|---|---|---|---|
440 VAC. | TO MOTOR |
Relay Range: 2.5-4 , 4-6.5 , 6-10 , 9-14
Suitable for Three Phase Submersible Pump, Open well & Monoblock Pumps Protection against Overload, Dry Run, Single Phasing, Reverse Phasing, and Unbalance.
R | Y | B | R | Y | B |
---|---|---|---|---|---|
440 VAC. | TO MOTOR |
Suitable Relay Range-3.8-6 , 6-9.3 ,9-13.4, 13-20
Suitable for Submersible, Open well and Monoblock Pump Controlling both suction and Delivery Tank operating on sensor or float switch.
Protection against Over load, Dry Run Single Phasing & Unbalance Voltage etc.
R | Y | B | R | Y | B |
---|---|---|---|---|---|
440 VAC. | TO MOTOR |
We at Powertek manufacture water level controllers, single phasing preventers, auto switches, timers, cyclic timers and control panels for single phase and three phase motors.We aim to facilitate and resolve any issues related to water management for different water levels in order to avoid wastage of water and electricity.