Panels

Specifications

SINGLE PHASE CONTROL PANEL (ELECTRONIC TYPE)

Suitable for Submersible Pump & Open well Pump Protections against Over load & Dry Run with Starting & Running Capacitors.

  • Input Voltage -230 VAC
  • Current Capacity -25 Amps. Max
  • Current Setting- 16 Amps. Max

Available for 0.5 H.P., 0.75 H.P., 1 H.P., 1.5 H.P. and 2 H.P.

Capacitors
H.P.0.5 H.P.0.75 H.P.1 H.P.1.5 H.P.2 H.P.
Running Capacitor25 Mfd30 Mfd36 Mfd36+25 Mfd36+36 Mfd
Starting Capacitor100/120 Mfd100/120 Mfd100/120 Mfd120/150 Mfd150/200 Mfd
Supply/Motor terminal
PNRYB
230VAC. SUPPLYTO MOTOR

 

SINGLE PHASE CONTROL PANEL WITH CONTACTOR & RELAY (ELECTRICAL TYPE)

Suitable for Single Phase Submersible Pumps with Starting and Running Capacitor with overload protection.

  • Input Voltage- 230 VAC.
  • Current Capacity- 15 Amp. Max.
  • Current Setting- 15 Amp. Max.

Available for- 0.5 H.P., 0.75 H.P., 1 H.P., 1.5 H.P., 2 H.P.

H.P.0.5 H.P.0.75 H.P.1 H.P.1.5 H.P.2 H.P.
Running Capacitor25 Mfd30 Mfd36 Mfd36+25 Mfd36+36 Mfd
Starting Capacitor100/120 Mfd100/120 Mfd100/120 Mfd120/150 Mfd150/200 Mfd
SUPPLY/MOTOR TERMINALS
PNRYB
230VAC. SUPPLYTO MOTOR

 

SINGLE PHASE CONTROL PANEL WITH WATER LEVEL CONTROLLER (ELECTRONIC TYPE)

Suitable for Single Phase Submersible Pump controlling both Suction and Delivery Tank, operating on Sensor or Float Switch with Auto cut off to Starting Capacitor.

Protection against Overload and Dry Run.

  • Input Voltage- 230 VAC.
  • Current Capacity- 18 Amp. Max.
  • Current Setting- 14 Amp. Max.

Available for- 0.5 H.P., 0.75 H.P., 1 H.P., 1.5 H.P., 2 H.P.

H.P.0.5 H.P.0.75 H.P.1 H.P.1.5 H.P.2 H.P.
Running Capacitor25 Mfd30 Mfd36 Mfd36+25 Mfd36+36 Mfd
Starting Capacitor100/120 Mfd100/120 Mfd100/120 Mfd120/150 Mfd150/200 Mfd
SUPPLY/MOTOR TERMINALS
PNRYB
230VAC. SUPPLYTO MOTOR

 

THREE PHASE CONTROL PANEL (ELECTRONIC TYPE)

Suitable for Three Phase Submersible Pump, Openwell Submersible Pump and Monoblock Pump.

Protection against Overload and Dry Run, Single Phasing, Reverse Phasing, Unbalance Voltage etc.

  • Capacity- 1 H.P. to 5 H.P.
  • Input Voltage: 440 VAC.
  • Current Capacity: 15 Amps. Max.
  • Current Setting: 15 Amps. Max.
Terminals
RYBRYB
440 VAC.TO MOTOR

 

THREE PHASE CONTROL PANEL WITH CONTACTOR, RELAY & MCB

Suitable for Three Phase Submersible Pump, Open Well & Monoblock Pump Protection against Overload, Dry Run, Single Phasing, Reverse Phasing & Unbalance Voltage

  • Capacity: 1 H.P. to 5 H.P.
  • Input Voltage: 440 VAC.
  • Current Capacity: 440 VAC.
  • Current Setting: 15 Amps. Max.
SUPPLY/MOTOR TERMINALS
RYBRYB
440 VAC.TO MOTOR

Relay Range: 2.5-4 , 4-6.5 , 6-10 , 9-14

 

THREE PHASE CONTROL PANEL WITH BCH CONTACTOR, RELAY & MCB ELECTRICAL TYPE

Suitable for Three Phase Submersible Pump, Open well & Monoblock Pumps Protection against Overload, Dry Run, Single Phasing, Reverse Phasing, and Unbalance.

  • Capacity: 1 H.P. to 7.5 H.P.
  • Input Voltage: 440 VAC
  • Current Capacity: 20 Amps. Max.
  • Current Setting: 20 Amps. Max.
SUPPLY/MOTOR TERMINALS
RYBRYB
440 VAC.TO MOTOR

Suitable Relay Range-3.8-6 , 6-9.3 ,9-13.4, 13-20

 

THREE PHASE CONTROL PANEL WITH WATER LEVEL CONTROLLER ( ELECTRONIC TYPE)

Suitable for Submersible, Open well and Monoblock Pump Controlling both suction and Delivery Tank operating on sensor or float switch.

Protection against Over load, Dry Run Single Phasing & Unbalance Voltage etc.

  • Capacity: 1 H.P. to 5 H.P. .
  • Input Voltage: 440 VAC. .
  • Current Capacity : 15 A. Max. .
  • Current Setting: 15 A. Max. .
SUPPLY/MOTOR TERMINALS
RYBRYB
440 VAC.TO MOTOR

Get In Touch